SteriPS Filter Cartridges
Single-layer PES Membrane · Sterilizing Grade

SteriPS Filter Cartridges are specially designed to provide a reliable sterilizing solution at an economical cost. Hydrophilic PES membrane cartridges require no pre-wetting and are ready to use. In addition, these filters provide good performance in pharmaceutical applications.


Features and Benefits

  • Low diffusion flow

  • Inherently hydrophilic PES membrane

  • High surface area design provides high flow rates and extended service life while maintaining high bacteria removal efficiency

  • Lower protein binding


Quality Standards:

  • Bacterial quantitative retention of 107 CFU/cm2 Brevundimonas Diminuta (ATCC 19146) according to ASTM F838 methodology .
  • 100% Integrity testing in manufacturing .
  • Each filter is fully traceable with serial number .
  • Manufactured in a facility which adheres to ISO 9001: 2015 Practices .
    • Bacterial Endotoxin : Aqueous extraction of autocalved filter contains <0.25 EU/ml as determined by Limulus Amebcyte Lysate (LAL),USP<85>.

    • Non-fiber Releasing : Component materials meet the criteria for a "Non-fiber-releasing filter" as defined in 21 CFR 210.3(b)(6).

    • Component Material Toxicity :Meet the requirement of USP <87> In Vitro Cytotoxicity Test ; Meet the Criteria of USP<88> Biological Reactivity Test for Class VI-121℃ plastics

    • TOC/Conductivity at 25 ℃:Autoclaved filter effluent meet the USP<643> for Total Organic Carbon and USP<645> for

    • Water Conductivity per WFI requirements after a UPW flush of specified volume .

    • Particle Shedding : Autoclaved filter effluent meet the USP<788>for large volume Injections .

    • Indirect Food Additive:All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182 , and EU framework regulation [1935/2004/EC].


Typical Applications

  • Antibiotics

  • LVP & SVP

  • Ophthalmic Solutions

  • Large Batch Solutions

  • Cleaning & Disinfecting Liquids


  • Specification
  • Performance
  • Ordering Information

Materials of Construction


Filter Media

PES Membrane

Support

Polypropylene

Core/Cage/End Caps

Polypropylene




Operating Conditions


Max. Operating Pressure

6.9 bar (100 psi) at 25 °C

4.0 bar (58 psi) at 60 °C

2.4 bar (35 psi) at 80 °C

Max. Differential Pressure

Forward

6.9 bar (100 psi) at 25 °C

4.0 bar (58 psi) at 60 °C

2.4 bar (35 psi) at 80 °C

Reverse

3.0 bar (44 psi) at 25 °C

1.0 bar (15 psi) at 80 °C

Effective Filtration Area0.58m² / Φ 69-10 inch




Sterilization


Inline Steam Sterilization

up to 100 cycles (135°C for 30min< 0.3 bar per cycle)

Autoclaveup to 200 cycles (130°C for 30min per cycle)

 


Integrity Test Data


Bubble Point

≥ 0.32 MPa (water), 0.22 μm
≥ 0.20 MPa (water), 0.45 μm

Diffusion Flow

≤ 25 ml/min/10”@ 0.275 Mpa, 0.22 μm
≤ 25 ml/min/10”@ 0.15 Mpa, 0.45 μm

 





 



Ordering Infomation



Removal RatingsEnd CapNominal LengthSeal MaterialIndustry

SPSHR 







0022=0.22μm

0045=0.45μm







HSF=226 /Fin (PBT Insert)

HSC=226 /Flat (PBT Insert)

HTF=222 /Fin (PBT Insert)

HTC=222 /Flat (PBT Insert)

DOE=Double Open End


05= 5"

10=10"

20=20"

30=30"

40=40"


S=Silicone

E=EPDM

V=Viton

P=PFA/Viton


P = Pharmaceutical






Contact Form
Corporate name* Department*
Name*
E-mail address*
Tel
Address
Leaving a message