TeflonFlow Filter Cartridges
Hydrophobic PTFE membrane · Sterilizing Grade

TeflonFlow Filter Cartridges are composed of a hydrophobic PTFE membrane. Characteristics include organic & inorganic corrosion resistance and it's inherently hydrophobic nature. These filters are ideally suited for the sterile filtration of solvents and corrosive and oxidized liquids.



Features and Benefits

  • Inherently hydrophobic
  • Broad chemical compatibility
  • High tolerance for aggressive acids and bases
  • High flow rates
  • Low extractable



Quality Standards:

  • Bacterial quantitative retention of 107 CFU/cm2 Brevundimonas Diminuta (ATCC 19146) according to ASTM F838 methodology .
  • 100% Integrity testing in manufacturing .
  • Each filter is fully traceable with unique serial number .
  • Manufactured in a facility which adheres to ISO 9001: 2015 Practices .

  • Full Regulatory Compliance with following :
    • Bacterial Endotoxin : Aqueous extraction of autocalved filter contains <0.25 EU/ml as determined by Limulus Amebcyte Lysate (LAL),USP<85>.

    • Non-fiber Releasing : Component materials meet the criteria for a "Non-fiber-releasing filter" as defined in 21 CFR 210.3(b)(6).

    • Component Material Toxicity :Meet the requirement of USP <87> In Vitro Cytotoxicity Test ; Meet the Criteria of USP<88> Biological Reactivity Test for Class VI-121℃ plastics

    • TOC/Conductivity at 25 ℃:Autoclaved filter effluent meet the USP<643> for Total Organic Carbon and USP<645> for

    • Water Conductivity per WFI requirements after a UPW flush of specified volume .

    • Particle Shedding : Autoclaved filter effluent meet the USP<788>for large volume Injections .

    • Indirect Food Additive:All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182 , and EU framework regulation [1935/2004/EC].


Typical Applications

  • Corrosive Liquid Sterilization and Particle Removal

  • Oxidized Liquids

  • Solvents



  • Specification
  • Performance
  • Ordering Information

Materials of Construction


Filter Media

Hydrophobic PTFE Membrane

Support

Polypropylene

Core/Cage/End Caps

Polypropylene




Operating Conditions


Max. Operating Pressure

6.9 bar (100 psi) at 25 °C

4.0 bar (58 psi) at 60 °C

2.4 bar (35 psi) at 80 °C

Max. Differential Pressure

Forward

6.9 bar (100 psi) at 25 °C

4.0 bar (58 psi) at 60 °C

2.4 bar (35 psi) at 80 °C

Reverse

3.0 bar (44 psi) at 25 °C

1.0 bar (15 psi) at 80 °C

Effective Filtration Area0.68-0.99m² / Φ 69-10 inch




Sterilization


Inline Steam Sterilization

up to 35 forward cycles (135°C for 30min < 0.3 bar per cycle.)

Autoclaveup to 120 cycles (130°C for 30min for every cycle)

 



Integrity Test Data


Bubble Point

BP: ≥ 0.11Mpa (60%/40%IPA/Water), 0.22μm

Diffusion FlowDF: ≤ 16ml/min/10”cartridge @80KPa (60%/40%IPA/Water) , 0.22μm

Water Intrusion Test

WFT : ≤ 0.38ml/min/10”cartridge @0.25MPa), 0.22μm

 





 



Flow Rate Characteristics



Ordering Infomation



Removal RatingsEnd CapNominal LengthSeal MaterialIndustry

LPF







0005=0.05μm

0010=0.1μm

0020=0.2μm

0045=0.45μm

0100=1.0μm

0300=3.0μm

0500=5.0μm




HSF=226 /Fin (PBT Insert)

HSC=226 /Flat (PBT Insert)

HTF=222 /Fin (PBT Insert)

HTC=222 /Flat (PBT Insert)

DOE=Double Open End


05= 5"

10=10"

20=20"

30=30"

40=40"


S=Silicone

E=EPDM

V=Viton

P=PFA/Viton


P=Pharmaceutical