TeflonFlow Filter Cartridges are composed of a hydrophobic PTFE membrane. Characteristics include organic & inorganic corrosion resistance and it's inherently hydrophobic nature. These filters are ideally suited for the sterile filtration of solvents and corrosive and oxidized liquids.
Manufactured in a facility which adheres to ISO 9001: 2015 Practices .
Full Regulatory Compliance with following :
• Bacterial Endotoxin : Aqueous extraction of autocalved filter contains <0.25 EU/ml as determined by Limulus Amebcyte Lysate (LAL),USP<85>.
• Non-fiber Releasing : Component materials meet the criteria for a "Non-fiber-releasing filter" as defined in 21 CFR 210.3(b)(6).
• Component Material Toxicity :Meet the requirement of USP <87> In Vitro Cytotoxicity Test ; Meet the Criteria of USP<88> Biological Reactivity Test for Class VI-121℃ plastics
• TOC/Conductivity at 25 ℃:Autoclaved filter effluent meet the USP<643> for Total Organic Carbon and USP<645> for
• Water Conductivity per WFI requirements after a UPW flush of specified volume .
• Particle Shedding : Autoclaved filter effluent meet the USP<788>for large volume Injections .
• Indirect Food Additive:All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182 , and EU framework regulation [1935/2004/EC].
Corrosive Liquid Sterilization and Particle Removal
Oxidized Liquids
Solvents
Materials of Construction
Filter Media | Hydrophobic PTFE Membrane |
Support | Polypropylene |
Core/Cage/End Caps | Polypropylene |
Operating Conditions
Max. Operating Pressure | 6.9 bar (100 psi) at 25 °C 4.0 bar (58 psi) at 60 °C 2.4 bar (35 psi) at 80 °C |
Max. Differential Pressure | Forward 6.9 bar (100 psi) at 25 °C 4.0 bar (58 psi) at 60 °C 2.4 bar (35 psi) at 80 °C Reverse 3.0 bar (44 psi) at 25 °C 1.0 bar (15 psi) at 80 °C |
Effective Filtration Area | 0.68-0.99m² / Φ 69-10 inch |
Sterilization
Inline Steam Sterilization | up to 35 forward cycles (135°C for 30min < 0.3 bar per cycle.) |
Autoclave | up to 120 cycles (130°C for 30min for every cycle) |
Integrity Test Data
Bubble Point | BP: ≥ 0.11Mpa (60%/40%IPA/Water), 0.22μm |
Diffusion Flow | DF: ≤ 16ml/min/10”cartridge @80KPa (60%/40%IPA/Water) , 0.22μm |
Water Intrusion Test | WFT : ≤ 0.38ml/min/10”cartridge @0.25MPa), 0.22μm |
Ordering Infomation
Removal Ratings | End Cap | Nominal Length | Seal Material | Industry | |
LPF | 0005=0.05μm 0010=0.1μm 0020=0.2μm 0045=0.45μm 0100=1.0μm 0300=3.0μm 0500=5.0μm | HSF=226 /Fin (PBT Insert) HSC=226 /Flat (PBT Insert) HTF=222 /Fin (PBT Insert) HTC=222 /Flat (PBT Insert) DOE=Double Open End | 05= 5" 10=10" 20=20" 30=30" 40=40" | S=Silicone E=EPDM V=Viton P=PFA/Viton | P=Pharmaceutical |